The UG045HD002 - Gas-fired humidifier 45 kg/h - 230 Vac single phase, features the highest thermal efficiency, so as to fully exploit the cost savings of gas. The heat exchanger, which is easily removable for cleaning, is made from aluminium alloy coated with a special corrosion-proofing and non-stick treatment that prevents the adhesion of lime scale. The gaSteam humidifiers all come with the new pHC electronic microprocessor controller that adopts all the best features of the pCO programmable controllers, one of CAREL’s main points of excellence. The user interface is made up of a backlit display that features the simultaneous and flexible use of graphic icons and texts in various languages.

More Information
Description

It features the highest thermal efficiency, so as to fully exploit the cost savings of gas. The heat exchanger, which is easily removable for cleaning, is made from aluminium alloy coated with a special corrosion-proofing and non-stick treatment that prevents the adhesion of lime scale. The gaSteam humidifiers all come with the new pHC electronic microprocessor controller that adopts all the best features of the pCO programmable controllers, one of CAREL’s main points of excellence. The user interface is made up of a backlit display that features the simultaneous and flexible use of graphic icons and texts in various languages. The pHC controller also comes with network connection: via the pCO family pLAN protocol (RS485 interface included), or the Modbus®, Echelon®, BACnet™, RS485 and GSM communication protocols using optional interfaces. The controller includes the independent control loop (humidity or temperature) with active probe and optional second limit probe, as well as the ON/OFF and proportional operating modes with signal from an external controller. It can also manage a dehumidifier, and includes a complete set of diagnostics for maintenance.

Safety:
GaSteam is fitted with various safety devices, including:

- Pre-mix, room-sealed burner with forced ventilation
- An air/gas control valve with double closing
- Safety negative pressure switch on combustion air intake
- Temperature sensor in the flue gas outlet that checks for malfunctions, and signals excessive accumulation of lime scale on
   the exchanger in advance
- A flame detector in the burner that closes the gas valve in the event of operating anomalies
- The patented AFS antifoam system with corresponding sensor
- A multi-stage water level sensor
- An automatic water conductivity control system to avoid corrosion

Added advantages:

- Continuous modulation from 25 to 100% (12.5% for the 180 kg/h model)
- Low NOx emissions
- Boiler and components in contact with the water in AISI 304L stainless steel
- Pre-heating function for a faster response
- Supply with mains water or demineralised water. The control can be set for use with softened water, within the limits
   described in the reference tables
- Antifreeze function
- Precision ± 2% rH

Manuals & Datasheets

BROCHURE

Code Description Language Date Release
+3000014EN The integrated solution for air handling unit control ENG 01/10/2012 1.0
+3000018EN Humidity matters! CAREL solutions for your humidification needs ENG 01/10/2012 2.0
+30U0018EN Humidity matters! CAREL solutions for your humidification needs (american format) ENG 01/03/2010 1.0
+302238596 Clean Rooms (american version) ENG 21/04/2010 1.1
+302240651 gaSteam Natural Power ENG 24/02/2009 1.0
+302240551 Humidity control in printing applications ENG 27/05/2008 1.0
+302238591 Humidity control in clean rooms ENG 12/09/2007 1.0
+302235436 Humidity control in textile applications ENG 02/07/2007 1.0
+302239381 Precision and Shelter units ENG 01/03/2006 1.0
+302238281 Integral control solution Air Handling Unit ENG 03/10/2005 3.0
+302240421 gaSteam 90 kg/h: the family gets bigger! ENG 01/10/2003 1.0
+302240221 Humidify & save! ENG 01/10/2001 2.0

MANUAL

Code Description Language Date Release
+030220931 gaSteam 45/90/180 HD002 microprocessor electronic controller ENG 11/01/2011 1.4
+030220486 Service humidification Isothermal and adiabatic humidifiers ENG 01/09/2008 1.0
+030220534 gaSteam 45/90/180 pHC control ENG 15/05/2006 1.2
Technical Information
Power supply 230 Vac (-15 to +10%), 50/60 Hz single-phase
Operating conditions 1T40 °C, 10 to 90% rH non-condensing
Storage conditions -10T70 °C, 5 to 95% rH non-condensing
Index of protection IP20
Rated steam production (kg/h) 45
Modulation of steam production 25 to 100%
Heat input - gross input power (kW) 34.8
Heat output - net output power (kW) 33
Power input at rated voltage (W) 250
Steam outlet pressure limits (Pa) 0 to 2000
Steam connection (O mm) 2x40
Gas connection 1" G
Types of gas Natural gas (G20 e G25); Propane (G31); Butane (G30)
Flow-rate/pressure on natural gas (G20) (m3St/h...Pa) 3.68/2000
Flow-rate/pressure on natural gas (G25) (m3St/h...Pa) 4.2/2000
Flow-rate/pressure on propane (G31) (m3St/h...Pa) 1.43/3000
Flow-rate/pressure on butane (G30) (m3St/h...Pa) 1.10/3000
Manufacturer Carel